BENDING STAND FOR FLAME CONTROL DEVICES
The equipment is designed to test flame control devices for bending in accordance with the requirements of GOST R 51843-2013 and other regulatory documents that have similar test requirements.
The test equipment is subject to certification according to GOST 8.568-2017.
Technical description:
The name of the characteristics | Nominal value | Tolerance |
Distance from the stand to the end of the pipe for installing the sample, mm, for the nominal diameter of the sample DN: - 6 mm, - 8 mm, - 10 mm, - 15 mm, - 20 mm, - 25 mm, - 32 mm, - 40 mm, - 50 mm |
12 16 20 30 40 50 64 80 100 |
least least least least least least least least least |
Length of pipes for application of force, mm, for nominal sample diameter DN: - 6 mm, - 8 mm, - 10 mm, - 15 mm, - 20 mm, - 25 mm, - 32 mm, - 40 mm, - 50 mm |
240 320 400 600 800 1000 1280 1600 2000 |
least least least least least least least least least |